condition monitoring

sensors and accessories

HOME | new | products | uses | apps | tech | faq | resellers | company | contact | video/audio | how easy

 
PLEASE NOTE YOU SHOULD CHECK THAT THE SENSOR & MOUNTING METHODS ARE SUITABLE FOR YOUR INDUSTRIAL ENVIRONMENT
 

AskForDemo.gif

small-ds1-sm1.gif
NEW - NEW - NEW - NEW
product code : MHC-DS1 / MHC-SM1
SMART SENSOR

click here to download file

 
Airborne sensor used for leak and vacuum detection
Detachable cable
Suitable for use with MHC-Memo Pro, MHC-Memo & MHC-Classic
83mm x 34mm O/D
prodair1.gif

click here to see video (1.22MB mwv file)

NEW - NEW - NEW - NEW
product code : MHC-Airborne
 
Airborne sensor used for leak and vacuum detection
Detachable cable
Suitable for use with MHC-Memo Pro, MHC-Memo & MHC-Classic
83mm x 34mm O/D

click here to download file

probe1.gif
product code : PROBE
 
Probe sensor used to access difficult to reach areas (e.g. in recesses etc.)
Detachable cable
MHC & 50 Ohm compatible variants
300-1000mm length x 34mm O/D

click here to download file

aess1small.gif
product code : AESS1
 
Low cost adhesive mount sensor
Painted or polyurethane dip coated options
54 x 35 x 14mm

click here to download file

studmountsensor1.gif
product code : X/10V/P

Permanently installed stainless steel sensor with M8 male stud fitting for mounting on machinery
Integral coax cable
MHC & 50 Ohm compatible variants
83mm x 34mm O/D

click here to download file

dipsensor1.gif
product code : X/10V/P/DP
 
Polyurethane dip coated permanently installed sensor with M8 male stud fitting for mounting on machinery
Integral coax cable
MHC & 50 Ohm compatible variants
83mm x 42mm O/D

click here to download file

ruggeddipped1.gif
product code : X/10V/WP
 
Waterproof ruggedised polyurethane potted permanently installed sensor with M8 male stud fitting for mounting on machinery
Integral coax cable
MHC & 50 Ohm compatible variants
83mm x 42mm O/D

click here to download file

ruggedsensor1.gif
product code : X/10V/P/DP
 
Extra ruggedised stainless steel sheathed, polyurethane potted, permanently installed sensor with M8 male stud fitting for mounting on machinery
Integral coax cable with conduit cable adaptor
MHC & 50 Ohm compatible variants
83mm x 42mm O/D

click here to download file

boss1.gif
product code : BOSS A
 
Mounting boss for M8 male stud mount sensor
Stainless steel
Bond or weld in place

click here to download file

raboss1.gif
product code : BOSS B
 
Right angle mounting boss for M8 male stud mount sensor
Stainless steel
Bond or weld in place

click here to download file

galvpad1.gif
product code : GP100
 
Monitoring pads used with MHC standard magnetic mounted sensors (e.g. as used with portable instruments) sold in packs of 100
Galvanised steel 25mm O/D
jb1.gif
product code : T/BOX/1/BNC
 
Junction boxes used to terminate cables from permanant sensor which are used periodically - available for 1,2,3,4,6 & 9 way sensor configurations
Grey powder coated

click here to download file

bracketsensor1.gif
product code : BRACKET90/BNC
Right angle bracket used to hold RF connector terminated cables for permanant sensor which are used periodically
Black spray painted

click here to download file

   

AskForDemo.gif

 
PLEASE NOTE YOU SHOULD CHECK THAT THE SENSOR & MOUNTING METHODS ARE SUITABLE FOR YOUR INDUSTRIAL ENVIRONMENT
 

Why are there so many sensor variants ?
 
Unfortunately everyone has different requirements for their site (e.g. immersed, high temp, size etc). As a result we provide sensors in different general formats which cater for most situations.
 
When selecting a sensor you should check that it is suitable for the equipment (e.g. MHC-Memo, MHC-Scanner etc.) and the environment (i.e. operating temperature, chemical resistance, cable length, size etc).
 
If you are unsure then please contact us.
 
 
Why should I use junction boxes and brackets
 
To maintain repeatable measurements it is important that the electrical signal from the sensor is noise free. By using accessories such as junction boxes & brackets you can keep the cables clean and tidy to ensure good readings.
 
 
 

What's the difference between MHC-standard and 50 Ohm sensors?
 
The main difference is that 50 Ohm sensors have a much lower output impedance which allows them to drive longer cables. However 50 Ohm sensors are only compatible with certain instruments. Be sure to check this before ordering. 
 
As a general rule the maximum recomended cable lengths for the different sensors are : 
 
MHC-Standard - up to 20m
MHC-50 Ohm - up to 100m
 
 
 
What adhesive is recommended bonding sensor, bosses & mounting pads
 
We normally recommend the use of a structural adhesive such as Loctite 326 with activator N (see www.loctite.com ). Other formulations should be checked for acoustic performance before use.
 
NOTE : YOU MUST CHECK IF THIS ADHESIVE IS SUITABLE FOR YOUR REQUIREMENTS AND THE ENVIRONMENT IN WHICH IT WILL BE USED 